To measure axial runout, place the indicator against the rotating face at a specified radius. For radial runout, contact the specified bore or locating diameter with the probe pointing radially. Turn the table through one full revolution for each reading. Report the high reading minus the low reading at each location.

Read the drawing before setting the indicator
A rotary table can have separate limits for the output face, inside register and outside register. Oriental Motor's DGII table precision drawings show these as distinct no-load checks. Use the contact locations and load condition specified for the actual model. Face runout describes the motion seen on a circular trace as the table turns. Flatness describes the surface itself and uses a different measurement. For a fixture located by a bore, the radial sweep at the bore usually matters more to centering than a reading from the outside edge.
Make the first sweep on the bare output table
- Clean the contact surface and mount the actuator on its intended base or inspection fixture. Tighten it in the sequence and to the values on the mounting instructions.
- Put the indicator stand on a stationary reference. Keep the bracket short and away from flexible covers. Align the probe with the direction being measured and set its working range so it stays in contact without bottoming out.
- Choose an angular reference and mark the start of the trace. Sweep one full turn at the approved inspection speed or use the measurement method stipulated for the unit. On the face, stay on the agreed track clear of holes and edge breaks.
- Record high and low readings, the positions where they occur and whether the start reading repeats at the end. Repeat the sweep before interpreting a small difference. If the return to the start disagrees, check for stand movement, dirt under the contact and temperature drift.
For example, at a 50 mm face radius, a maximum of +0.012 mm and a minimum of −0.008 mm give 0.020 mm total indicator reading. Compare 0.020 mm with the limit for that check. Report the radius with the result, because moving the probe changes how much a tilt contributes to the reading. For a bore or outside register, record the contact height too. A smooth once-per-turn rise on the face can be consistent with tilt. A sharp isolated peak calls for a surface inspection before any adjustment.
Repeat at the fixture if the process depends on it
Keep the bare-table result as a baseline. Measure the installed fixture at the surface that locates the workpiece. Log the fastener condition, payload and its offset. If the bare table passes but the fixture fails, inspect the seating faces, pilot fit and clamp sequence. If the reading changes with eccentric load, look at the moment applied to the table and the stiffness of the fixture and base. Use the axial, radial and moment load check to describe that load case.
| Result to record | Where the probe contacts | Condition to record |
|---|---|---|
| Output face runout | Agreed radius on the bare face | Base, clamp condition and direction |
| Register runout | Specified bore or outside diameter | Probe height, angle reference and load condition |
| Fixture runout | Workpiece locating face or pilot | Fixture model, fasteners and applied load |

For a LIMON DYH rotary platform enquiry, attach the fixture drawing and identify the exact face or diameter that controls the process. Include the test radius or height, maximum reading allowed and the mounting and loading conditions in your request.