Centre technique

Illustrative profile guide assemblies for comparing catalog load-rating conventions
Centre technique

Linear Guide Load Ratings: Comparing 50 km and 100 km Values

A dynamic load rating based on 50 km cannot be compared directly with one based on 100 km. For a ball-type linear guide using the same cubic life model, divide the 50 km rating by approximately 1.26 to express it on a 100 km basis. That conversion changes the reference basis, not the guide’s physic

Illustration d'un ensemble à deux rails et d'un contact indicateur pour les contrôles d'alignement
Centre technique

Comment mesurer le parallélisme entre deux rails linéaires

Measure linear rail parallelism by moving a repeatable reference along one established rail and recording the relative position of the second rail. Check lateral separation and height difference separately, then repeat after final tightening. A carriage that travels freely is useful evidence of ass

Illustration of a profile rail and guide block on a machined mounting base
Centre technique

Linear Guide Datum Shoulders: Height, Relief and Contact

A linear guide datum shoulder locates the rail or carriage against a reference face. Its height, corner relief and stiffness must match the selected guide drawing. A shoulder that is too high can foul the moving block; an oversized corner radius can prevent the rail from seating even when the mount

Engineering illustration of the motor, ball screw and carriage in an electric linear actuator.
Centre technique

Comment fonctionne un actionneur linéaire ?

Le fonctionnement imprécis d'un actionneur entraîne-t-il un mauvais dimensionnement, un mouvement instable, une usure prématurée ou des modifications coûteuses de la conception de la machine ? : Un actionneur linéaire…